Platform-specific documentation/Sun Fire V20z/V40z
The V20z is a 1U rack server, the V40z is 3U.
- V40z
- pascal, vandale, zedler (toolserver)
- V20z
- mint, fuchsia, lily, hawthorn, mayflower, iris, clematis, sage, ragweed
Specification
- Up to two/four Opteron sockets
- Two Gigabit ports
- Supports Sun IPMI Service Processor
Lights Out Management
Connect to hostname.ipmi.knams from within KNAMS.
Common Actions
Serial Console
Log in with SSH and use the command
platform console
Disconnect from the console with
Ctrl-E c .
If the console is used by someone else, you'll get a read only session. To disconnect the other session and get a read/write session, type
Ctrl-E c f
Power Cycling
To reboot a server, log in with SSH and use the command
platform set power state cycle
If it won't, try
platform set power state -W -f off
You can check that it's off with
platform get power state
Then you can power it back on with
platform set power state -W -f on
Help
help