Incident documentation/20110524-PlannedMaintenance
Summary Report - Planned Network Maintenance, May 24, 2011 (13:00 UTC to 14:00 UTC)
Background
On 10th May, Ops noticed some IRC traffic commenting the site was slow. Mark investigated and concluded it is probably caused by a full in-memory table (CAM) in the router. As an interim measure, he performed some traffic rerouting on the routers and that alleviated the issue. However, the fix was meant to be temporary.
The following day, Mark noticed there were packet losses with that router. Users were again commenting and complaining about page load lag. Upon further investigation, he decided the router software needed to be upgraded and tuned. However that would required substantial amount of work and downtime and since many of our operations engineers were either enroute or preparing for the trip to Berlin, Mark decided to perform another temporary (and unfortunately intrusive) fix, a short reboot on one of the routers. That reboot took 3 minutes. That seems to clear the problem.
There were again reported long page load lag time surfacing the following week especially on 20th May. Mark investigated and found the problematic router experienced an internal network fail-over. That caused some multicasting failures. (Ganglia reporting was one of the casualties). However, there were insufficient data available to determine the fail-over root cause.
The Plan & Goals
The plan to address the router problem was finalized. The maintenance was scheduled on Tuesday, 24th May. The plan consists of:
a. Mark performs some preparatory work on the routers before 13:00 UTC b. RobH lines up Equinix Tampa to be on standby c. Domas will be on standby to help should the database servers not respond to the network changes (known to have happened before) d. During the maintenance window, Mark will: - upgrade and reload csw1-sdpta (Foundry router located in SDPTA) - upgrade and reload csw5-pmtpa (Foundry router located in PMTPA) - upgrade the Juniper EX stack in row B - upgrade Foundry switch on D1 - upgrade the rest of the 4 Foundry switches
With this maintenance, the goals are to :
- address the sporadic and somehow isolated long lag times in some of the page loads - fix the multicast problem (that caused some caching issue) - increase the CAM table partition size (some network table in the router for traffic routing) - upgrade & patch the router and switches operating softwares
The Maintenance
Shortly after 13:00 UTC, Mark started the upgrade. It took 1 hour to perform all but 1 of the above. The Juniper EX stack was not upgraded (not a problem) because he ran out of the maintenance window. During the maintenance window, the site was intermittently unavailable because of the reboots. One of the (slave) databases went down and was taken out of the cluster. Some of the database servers did not recover gracefully and Domas determined the 'Forcedeth' driver for the NIC (network interface card) was the culprit. Together with the help of RobH and Ariel, all the impacted servers recovered.
24-hour Later
The team performed the operation successfully - the upgrades and reboots on those network gears went smoothly and the servers and sites came back up on scheduled. We believe we have also addressed the lag in the page load caused by the network routing problem. Meanwhile, we are continuing to monitor the situation.