Incident documentation/20151022-EventLogging
Summary
On Monday, October 26, 2015, we found out that data was no longer replicated for about 80 tables from m4-master to analytics-store (dbstore1002 not dbstore2002) as was visible to stat1003. All dashboards, research, etc. against these schemas (listed below) will be invalid until this data is backfilled from m4.
This was caused by schema changes done on Task T108856, combined with the replication model not using standard mysql replication, using a 3rd party script to clone data. This meant that schema changes were not replicated, and as a consequence, the copy script failed on all tables alphabetically after the first one with a different schema.
The schema change was applied to all tables and the script is backfilling slowly all rows.
Timeline
- 2015-10-08 (not directly related) I delete some tables from the log schema, and I notice that the tables were recreated automatically. I am puzzled by it, but cannot do anything, as they do not reappear again. (they were being recreated by the "custom replication" process)
- 2015-10-22 15:52 A schema change is rolled on db1046. Everything seems ok after the change, but starting from that time, results may not be accurate
- 2015-10-26 14:39 milimetric informs jynus of an issue with the m4 (eventlogging) database on chat
- 2015-10-26 19:08 jynus finds the custom script failing to copy the events. Ori and others confirm its existence some minutes later. Schema is changed a few minutes after that and the script starts to backfill events from the master.
- 2015-10-27 08:24 All events are synced again with the master.
Ticket: [1]
Actionables
- Status: Done Backfill missing data from m4.
- Status: Done Document better the analytics replication model.
- Status: Done Puppetize the copy script (otherwise, it will fail on server reboot).
- Status: Done Implement better monitoring of the custom replication on db1047 and dbstore1002 . Although it can be improved by monitoring the lag, too.
Schemas with Missing data
CompletionSuggestions_13630018 GatherClicks_12114785 GeoFeatures_12518424 GeoFeatures_12914994 GettingStartedRedirectImpression_7355552 GuidedTourButtonClick_13869649 GuidedTourExited_8690566 GuidedTourExternalLinkActivation_8690560 GuidedTourGuiderHidden_8690549 GuidedTourGuiderImpression_8694395 ImageMetricsCorsSupport_11686678 ImageMetricsLoadingTime_10078363 MediaViewer_10867062 MobileAppCategorizationAttempts_5359208 MobileAppLoginAttempts_5257721 MobileAppUploadAttempts_5334329 MobileOptionsTracking_14003392 MobileWebBrowse_12119641 MobileWebClickTracking_5929948 MobileWebDiffClickTracking_10720373 MobileWebEditing_8599025 MobileWebMainMenuClickTracking_11568715 MobileWebSearch_12054448 MobileWebUIClickTracking_10742159 MobileWebWatching_11761466 MobileWebWatchlistClickTracking_10720361 MobileWikiAppAppearanceSettings_10375462 MobileWikiAppAppearanceSettings_9378399 MobileWikiAppArticleSuggestions_10590869 MobileWikiAppArticleSuggestions_11448426 MobileWikiAppArticleSuggestions_12443791 MobileWikiAppCreateAccount_8240702 MobileWikiAppCreateAccount_9135391 MobileWikiAppDailyStats_12637385 MobileWikiAppEdit_9003125 MobileWikiAppInstallReferrer_12601905 MobileWikiAppLangSelect_12588733 MobileWikiAppLinkPreview_12143205 MobileWikiAppLogin_8234533 MobileWikiAppLogin_9135390 MobileWikiAppMediaGallery_10923135 MobileWikiAppMediaGallery_12588701 MobileWikiAppNavMenu_12732211 MobileWikiAppOnboarding_9123466 MobileWikiAppOperatorCode_8983918 MobileWikiAppProtectedEditAttempt_8682497 MobileWikiAppSavedPages_10375480 MobileWikiAppSavedPages_8909354 MobileWikiAppSearch_10641988 MobileWikiAppShareAFact_11331974 MobileWikiAppShareAFact_12588711 MobileWikiAppStuffHappens_8955468 MobileWikiAppTabs_12453651 MobileWikiAppToCInteraction_10375484 MobileWikiAppToCInteraction_11014396 MobileWikiAppToCInteraction_8461467 MobileWikiAppWidgets_11312870 MultimediaViewerAttribution_9758179 MultimediaViewerDimensions_10014238 MultimediaViewerDuration_10427980 MultimediaViewerNetworkPerformance_12458951 MultimediaViewerVersusPageFilePerformance_7907636 NavigationTiming_10785754 NavigationTiming_12405818 NavigationTiming_13317958 NavigationTiming_13332008 NewEditorEdit_6792669 PageContentSaveComplete_5588433 PageCreation_7481635 PageDeletion_7481655 PageMove_7495717 PageRestoration_7758372 Popups_11625443 PrefUpdate_5563398 SaveTiming_12236257 ServerSideAccountCreation_5487345 TestSearchSatisfaction2_13223897 TestSearchSatisfaction2_14098806 UniversalLanguageSelector_7327441 UploadWizardErrorFlowEvent_11772725 UploadWizardFlowEvent_11772723 UploadWizardStep_11772724 UploadWizardTutorialActions_5803466 UploadWizardUploadFlowEvent_11772717 WikimediaBlogVisit_5308166